demonstrations:8_astronomy:transit_method:start [2023/08/11 18:43] – [Setup] demoroomdemonstrations:8_astronomy:transit_method:start [2023/08/11 20:02] (current) – [Setup] demoroom
Line 34: Line 34:
 ===== Setup ===== ===== Setup =====
  
-Suspend the diffuse light source above the rotating table.  Attach a model exoplanet to the rotating table. +  - Mount the rotating table on a sufficiently large and sturdy table. 
-Connect the power source (EICO 1064) to the motor in the rotating table.  Start at 0V and slowly turn up the voltage until a desired rotation rate is obtained.  Mount the light sensor a suitable distance away so that when the table rotates a periodic decrease in the intensity will be observed.  Connect the light sensor to the Vernier LabPro interface.  Connect the Vernier LabPro interface to the USB port of a computer with LoggerPro installed.  Power the interface, wait for the beeps to finish and then start the LoggerPro software. +  - Cover the rotating table with a black cloth. 
 +  - Suspend the diffuse light source above the rotating table. 
 +  Attach a model exoplanet to the rotating table. 
 +  Connect the power source (EICO 1064) to the motor in the rotating table. 
 +  Start at 0V and slowly turn up the voltage until a desired rotation rate is obtained.  
 +  -  Mount the light sensor a suitable distance away so that when the table rotates a periodic decrease in the intensity will be observed.   
 +  - Connect the light sensor to the Vernier LabPro interface.   
 +  - Connect the Vernier LabPro interface to the USB port of a computer with LoggerPro installed. 
 +  Power the interface, wait for the beeps to finish and then start the LoggerPro software. 
  
 {{:demonstrations:8_astronomy:transit_method:transitmethodsetup.jpg?400|}} {{:demonstrations:8_astronomy:transit_method:transitmethodsetup.jpg?400|}}
 +
 ===== Notes ===== ===== Notes =====
  
Line 59: Line 68:
 </WRAP> </WRAP>
 <WRAP tablewidth 100%> <WRAP tablewidth 100%>
-| **Location** | Hebb 100a on shelf next to the personal desk |+| **Location** | Hebb 100a on a grey metal shelf on the same side as the personal desk|
 | **Maker** | Unknown | | **Maker** | Unknown |
 | **Current State** | Working | | **Current State** | Working |