demonstrations:4_thermodynamics:4e_gas_law:compression_igniter:start
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| demonstrations:4_thermodynamics:4e_gas_law:compression_igniter:start [2019/02/14 23:33] – external edit 127.0.0.1 | demonstrations:4_thermodynamics:4e_gas_law:compression_igniter:start [2020/03/13 20:30] (current) – demoroom | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Compression Igniter ====== | ====== Compression Igniter ====== | ||
| - | {{tag>ignite | + | {{tag> |
| <WRAP box right> | <WRAP box right> | ||
| Line 11: | Line 11: | ||
| ===== Description ===== | ===== Description ===== | ||
| - | Light a piece of tissue on fire using pressure. | + | Consists of a glass tube mounted inside a bigger plastic tube. A brass screw fitting is installed in the bottom so a metal base can be screwed in. A plunger with a seal at the end is inserted into the top of the tube. |
| - | + | ||
| - | + | ||
| - | + | ||
| ===== Purpose ===== | ===== Purpose ===== | ||
| + | Light a piece of tissue on fire via (approximately) adiabatic compression of gas. Demonstrates an example of one type of thermodynamic process. Shows how the ideal gas law can be used to predict what happens when a volume of air is rapidly compressed. Additionally can be used to demonstrate the flash point of cotton; certain materials spontaneously ignite when exposed to sufficiently high temperatures. | ||
| ===== Apparatus ===== | ===== Apparatus ===== | ||
| - | + | * Compression igniter | |
| - | Compression igniter, tissue or cotton | + | * tissue or cotton |
| - | + | ||
| ===== Setup ===== | ===== Setup ===== | ||
| + | - Place a small piece of flammable material((brown paper towels bought in stores work, cotton balls work best. The greater the surface-area-to-mass ratio, the better.)) in the glass tube by unscrewing the bottom platform. You can also drop it into the top and use a ramrod to push it down. | ||
| + | - Before screwing the platform back, ensure the piston/ | ||
| + | - Push down quickly with a significant force. | ||
| + | - If the demo is to be done more than once, remove the plunger and base platform, and then push a piece of tissue through the glass tube with the wire to clean it between each attempt. | ||
| - | + | Currently there are three compression igniters available, two newer professional models, and one cheap blue plastic model. | |
| - | 1. Place a small piece of tissue/ | + | |
| - | 2. Before screwing the platform back, ensure the piston/ | + | |
| - | 3. Push down quickly with a significant force. | + | |
| - | 4. If the demo is to be done more than once, remove the plunger and base platform, and then push a piece of tissue through the glass tube with the wire to clean it between each attempt. | + | |
| - | + | ||
| - | + | ||
| - | Currently there are three compression igniters available, two newer professional models | + | |
| - | + | ||
| - | The cheap model is mostly for loan out to events or grad students, the newer model is used for lecture and instructing purpose. Cheap model can be found in Orange Closet. | + | |
| ===== Notes ===== | ===== Notes ===== | ||
| - | If the plunger is not pushed fast enough, the tissue will smoke but not ignite. | + | If the plunger is not pushed fast enough, the tissue will smoke but not ignite. |
| - | + | ||
| - | <iframe title=" | + | |
| <WRAP group> | <WRAP group> | ||
| Line 63: | Line 49: | ||
| </ | </ | ||
| <WRAP tablewidth 100%> | <WRAP tablewidth 100%> | ||
| - | | **Location** | ---- | | + | | **Location** | C3 | |
| | **Maker** | Unknown | | | **Maker** | Unknown | | ||
| | **Current State** | Working | | | **Current State** | Working | | ||
demonstrations/4_thermodynamics/4e_gas_law/compression_igniter/start.1550187203.txt.gz · Last modified: by 127.0.0.1